Single phase only. Guards recommended. This configuration is not recommended for electroless chemistry, phosphoric acid, or applications prone to sludge buildup. Longer vertical lengths and flexible risers available, consult factory.

Unit of Measure

Specifications

Series

HXF Series

Watts

3000 W

Watt Density

10 W/in²1.5 W/cm²

Volts

240 V

Hot Zone

10 "254 mm

Overall Length

23 "584 mm

Diameter

9 "229 mm

Std. Cold Zone

13 "330 mm

Max. Cold Zone

35 "889 mm

Material

Fluoropolymer

Phase

Single

Shipping Weight

13.0 Pound
Options Available1 Comes Standard with Replaceable thermal protector: P1: for solutions up to 180°F (82°C). Resettable thermal protector: P2: for solutions up to 180°F (82°C). Resettable thermal protector: P3: for solutions up to 250°F (121°C). Resettable thermal protector: P8: for solutions up to 210°F (99°C).

Guards Recommended

Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

Guard Model Number

HXF09-23G

Construction

Ground wire is welded to stainless steel sheath.

Certifications


CE

CSA

UL Listed

Manufacturer

Process Technology

Weight

13.0 lbs5.9 kg
  • 1 Consult factory